Skip to main content
The GeoComfort RT outdoor split heat pumps can provide forced air heating and cooling, hot water assists for 25%–40% savings on hot water costs annually, or can be used with a conventional furnace to create a dual-fuel system for optimal energy savings. The RT models are similar to the BS/BT indoor split systems, except the RT is installed outside, making these systems perfect for applications where there isn’t space for a unit indoors, like in small homes or buildings.

Compatible With The DX Air Handler — Built By Enertech

Unlock the full potential of your geothermal split system for forced air applications with the direct expansion (DX) air handler.
FEATURES
  • Available sizes: 2–5 tons
  • Efficiencies: Up to 25.4 EER / 4.4 COP
  • Hot water assist
  • Heavy gauge steel
  • Two-stage compressor
  • Temperature sensor as part of system safeties
Document Downloads:
Model Specifications:
Model RT024
CAPACITY Full Load Part Load
COOLING BTU/HR 25,800 20,700
COOLING EER 16.90 22.50
HEATING BTU/HR 18,700 15,600
HEATING COP 3.60 3.90
Model RT036
CAPACITY Full Load Part Load
COOLING BTU/HR 37,500 29,700
COOLING EER 18.50 27.20
HEATING BTU/HR 28,300 22,500
HEATING COP 4.10 4.60
Model RT048
CAPACITY Full Load Part Load
COOLING BTU/HR 49,800 38,800
COOLING EER 17.90 25.00
HEATING BTU/HR 38,500 30,800
HEATING COP 3.70 4.30
Model RT060
CAPACITY Full Load Part Load
COOLING BTU/HR 60,500 47,700
COOLING EER 17.40 24.30
HEATING BTU/HR 46,200 36,200
HEATING COP 3.60 4.10
renewaire ev premium m e083e093

ERV’s

equipment pads f8f3955a

Equipment Pads

alphi11 jug 43051645

Antifreeze

hydronic air handler 60d09d41

Multi-Position Hydronic Air-Handlers

flow center df0059ff

Flow Centers

external heater bda4d42b

Auxiliary Heaters

24v electrostatic filter 930cc705

Electronic Dynamic Filter

zone control 44dd1050

EWC Zoning Dampers and Panels

sensi touch bcfae102

Thermostats

multiaqua a8223d2a

Multi-aqua Fan Coils

We offer many optional accessories for each of our geothermal units: